Re: Switch Temperature Monitoring
This resource cannot be used for Hardware Health Sensor info. You can try a Custom Chart instead - see here.Multiple Node Temperature Chart
View ArticleRe: Unknown error with code:87
Never seen anything like it. Any screenshots? Is it affecting devices in another location than the NPM server? How often does it happen?
View ArticleAlerts - job alerts on a table/report
hello guys, here is my predicament. we have emails alerting us of jobs that failed on a regular basis.this is causing 'alert burning/annoying/'what da heck feeling' instead, i would like to have a way...
View ArticleRe: Question for Spread the Word ?
Hi amitkumar,Since the US office was on holiday on Thursday and on Friday, there will be a slight delay regarding the Amazon cards.I apologize for the inconvenience and I can assure that you will...
View ArticleRe: ping component monitor for external nodes?
You will have to change the node type to SNMP. Presumably, you added that as an External node because ICMP was blocked and didn't want it show up as down. Now that you can determine status purely via...
View ArticleRe: Dynamic IP address and a possible problem/bug
This behavior would be expected at present. The results of the last A record lookup for that host are stored in the DB. In the event DNS lookup fails, NPM is still able to poll the device via...
View ArticleRe: ping component monitor for external nodes?
Presumably, you added that as an External node because ICMP was blocked and didn't want it show up as down. Now that you can determine status purely via SNMP, you can change the node type to...
View ArticleRe: Re: ping component monitor for external nodes?
Is SNMP polling allowed on the external node? If so, click on 'List resources' for the node and change the 'Status & Response time' option from ICMP to SNMPWell, I prefaced with "Is SNMP polling...
View ArticleRe: WAN Interface Utilization Help
1 and 4 can be achieved through the alert manager using the 'Do not trigger until condition exists for more than' setting. 2 and 3 requires custom SQL
View ArticleRe: Re: Re: ping component monitor for external nodes?
"The Ping will be performed from the Windows node that this template will be assigned to."I think the purpose of this template is to check if node A can ping node B. The monitor's stats remain with...
View ArticleRe: Backup HP V1910 (Legacy 3Com 2928) switch
Yes, I am. For HP seems like only 2 scripts exist, HP.2500 and HP.others. None works. Do you have a solution for this?(The closest I get is with HP.others but I just cant seem to be able to make it...
View ArticleRe: Alerts - job alerts on a table/report
while i wait for a better alternative this is what i have done. created a function that returns the data set that we requiredump this into Excel it would be nice if i could use this data set as a basis...
View ArticleRe: I CAN'T ADD OSN 8800 ON NPM, HELPING TIP PLS
If you've configured the device for SNMP access, than more then likely the device doesn't support the RFC MIB-2 requests coming from SolarWinds. To test this, you can open the PollerChecker.exe on the...
View ArticleRe: Additional Polling Engine Release Notes and upgrade recommendations
With the way the bundle installer is working, it's going to check your main poller to see what modules you have installed. It will then download the same version of that module for the additional...
View ArticleDo you have the capability of automatically assigning an email ticket to a...
We have 2 main email addresses that will create tickets for my company. I was wondering if there was a way to designate an auto assignment based on which email address was used. So if ticket A comes...
View ArticleDatabase Query to link AlertLog table contents with the AuditingEvents table...
Hi All, I am trying to build a custom report for our NOC team to extract the alert information(mostly Historical) for any given Node in Orion from the ALertLog table (which contents the alert info that...
View ArticleRe: NPM Monitoring Network flapping
No I dont , which is very odd Other devices are fine Steve Iliadis Integrated Technology TeamCity of Toronto - Toronto Water Division 60 Tiffield Rd, Scarborough, ON, M1V 5N2 (416) 397-9767
View ArticleRe: Standalone NCM v7 Question
Hi, What you can do is set maximum polling and status collecting intervals. (Edit node properties) All three input boxes above accept maximum value of 32767 (of the indicated unit). Regards,Jiri
View Article